Call us today:
(+234) 802 290 1866
(+234) 803 333 9602

Products - Anton Paar


1. Alcohol Analysis

2. Analysis of Dissolved Gases

3. Beer Analysis

4. Custom-tailored Automation for Analytical Workflows

5. Density and Concentration Determination

Density Meter: DMA 500

DMA 500 is a compact digital density meter providing unrivaled ease of use. The self-explanatory user interface allows you to single-handedly operate the instrument within a few moments.

The instrument comes with features that support the correct filling of your sample and ensure fully traceable measurement results that are ready in next to no time. Building on its integrated rechargeable battery, you can easily take the instrument off the line for operation outside the traditional lab space. Furthermore, voltage fluctuations or power outages are no threat for DMA 500: You can continue your measurements as planned without losing any data and time.
Measuring range:
Density: 0 g/cm³ to 3 g/cm³
Temperature: 15 °C to 40 °C (59 °F to 104 °F)
Pressure 0 bar to 3 bar (0 psi to 43.5 psi)
Accuracy
Density 0.001 g/cm³
Temperatur 0.3 °C
Repeatability s.d.
Density 0.0002 g/cm³
Temperature 0.1 °C
Additional information
Minimum sample volume approx. 1 mL
Predefined tables and functions
Alcohol tables
Sugar/extract tables
Acid/base tables
API functions
Ten programmable custom functions
Controls Softkeys, optional keyboard or bar code reader Interfaces
1 x Bluetooth
2 x USB
1 x Ethernet
Internal storage 1000 measured results
Weight 2.5 kg (5.5 lbs)
Dimensions
(L x W x H) 210 mm x 200 mm x 135 mm (8.3 in x 7.9 in x 5.3 in) Wetted parts PTFE, borosilicate glass
Power supply AC 100 - 240 V, 50/60 Hz, 1.4 A DC 12 V, 5 A
Rechargeable battery type Li-Ion 7.4 V, 2.25 Ah (optional: Li-Ion 7.5 V, 4.8 Ah)
Maximum off-the-line operation 2 hours (6 hours with optional high-performance battery)


2. CarboQC

is the precise CO2 meter which allows reliable QC on finished packages as well as highly accurate measurements in the laboratory for product development. It gives you fast, accurate and reliable determination of dissolved carbon dioxide in beverages. When combined with Anton Paar’s PFD filling device, sample is taken directly from the package into the measuring chamber of CarboQC - with no loss of dissolved carbon dioxide during sample transfer.

CarboQC for the laboratory provides reliable CO2 results, even out of very small packages.
Measuringrange: CO2 0 g/L to 12 g/L(0 vol. to 6vol.) at 30 °C
0g/L to 20 g/L (0 vol. to 10 vol.) < 15 °C
Temperature: -3 °C to +40°C (27°F to 104°F),
Accuracy: ± 0.2 °C
Pressure: 0 bar to 10bar absolute (0 psi to 145 psi)
Repeatability s.d. CO2 0.01 g/L (0.005 vol.)
Reproducibilitys.d. CO2 0.05 g/L (0.025 vol.)
Resolution CO2 0.001 g/L
Additionalinformation Sample volume approx. 100 mL
Measuring timeper sample approx. 55 seconds
Internalstorage 500 measured results
Interfaces 1 x RS-232 for PC and printer
1 x USB for PC
1 x RFID, 1 x Bluetooth (optional)
Protectionclass IP67 Power supply AC 100 - 240 V, 50/60 Hz,1.5 A DC 12 V, 3.,0 A
Rechargeablebattery type Li-Ion 11.1 V, 2.25 Ah(optional: Li-Ion 11.25 V, 2.6 Ah) Maximumat-line operation 10 hours
Dimensions (Lx W x H) 258 mm x 201 mm x 170 mm(10.2 in x 7.9 in x 6.7 in)
Weight 2.0 kg (4.4 lbs)



4. External Measuring Cell: DMA 4100

The External Measuring Cell DMA HP measures density and specific gravity at sample pressures up to 700 bar (10,000 psi) and temperatures up to 200 °C (392 °F). Connect a DMA 4100 M, DMA 4500 M, DMA 5000 M or DSA 5000 M to control DMA HP and read out the measurement data

Measuring range
Density 0 to 3 g/cm3
Temperature -10 to +200 °C (14 to 392 °F)
Pressure 0 to 700 bar (0 to 10,000 psi)
Accuracy
Density Up to 0.0001 g/cm3
Temperature 0.05 °C (0.09 °F)
Repeatability s.d.
Density Up to 0.00001 g/cm3 Resolution
Evaluation unit DMA 4100 M 0.0001 g/cm3
Evaluation unit DMA 4500 M 0.00001 g/cm3
Evaluation unit DMA/DSA 5000 M 0.000001 g/cm3
Additional information
Cell material Hastelloy C-276
Volume of the measuring cell approx. 2 mL
Dimensions / Weight 440 x 315 x 220 mm / 24 kg
(17.3 x 12.4 x 8.7 inches / 52.9 lbs) Power supply AC 100 to 240 V , 50 to 60 Hz, 330 VA
Connections Pressure fittings for metal tubes with 1/8" outer diameter
Interfaces RS-232 computer interface,S-BUS interfaces,external analog input

5. Density Measuring Module: DMA 4500 ME

The DMA 4500 ME density measuring module determines a liquid’s density or concentration. The measurement is based on the proven oscillating U-tube principle ensuring highly accurate density values. DMA 4500 ME can be combined with master instruments of the Alcolyzer M series.


Measuring Range
Density 0 g/cm3 to 1.5 g/cm3
Temperature 15 °C to 25°C (59 °F to 77 °F)
Pressure 0 bar to 6 bar (0 psito 87 psi)
Repeatabilitys. d.
Density 0.0/0001 g/cm3
Temperature 0.01 °C
AdditionalInformation
Minimum samplevolume approx. 2 mL
Dimensions (L xW x H) 400 mm x 225 mm x 231 mm(15.7 in x 8.6 in x 9.1 in)
Weight approx. 15 kg (33.1 lbs)
Automatic bubbledetection yes
Reference oscillator yes
Full range viscosity correction yes
Schnittstellen 2 x CAN
Power: supplied by the master instrument

6. Density Meters: DMA Generation M

The DMA 5000 M is the most accurate density meter on the market and is ideal for numerous fields of application and successful continuous operation in the laboratory. First-class digital density measurement provided by the robust DMA Generation M density meters is applied in industrial quality control, in research, at authorities and standards organizations.

This series of density meters provides unparalleled ease-of-use at an attractive price and ensure complete transparency and traceability of the sample fillingx and measurement process.

DMA 4100 M DMA 4500 M DMA 5000 M
Measuring range Density: 0 g/cm³ to 3 g/cm³
Temperature: 0 °C to 95 °C (32 °F to 203°F)
Pressure: 0 to 10 bar (0 to 145 psi)
Accuracy Density: 0.0001 g/cm³ Temperature: 0.05 °C/0.09 °F Density: 0.00005 g/cm³
Temperature: 0.03 °C/0.05 °F Density: 0.000005 g/cm³ Temperature: 0.01 °C/0.02 °F
Repeatability s.d.
Density: 0.00005 g/cm³
Temperature:
0.02 °C/0.04 °F Density: 0.00001 g/cm³
Temperature: 0.01 °C/0.02 °F
Density: 0.000001 g/cm³ Temperature: 0.001°C/0.002°F Integrated tables and functions
Alcohol tables
Extract/sugar tables
API functions
Acid/base tables
20 freely programmable tables/user functions (tables, polynomials, formulas, linear functions and constants) Minimum sample amount approx. 1 mL
Measuring time per sample* 30 seconds 40 seconds
Dimensions (L x W x H) 482 x 340 x 231 mm (19 x 13.4 x 9.1 inches)
Data memory 1000 measurement results (optional ring memory) Power supply AC 100 to 240 V; 50 to 60 Hz; 190 VA Weight 22.5 kg (49.6 lbs)
Interfaces
4 x USB 2 x S-BUS RS-232 CAN VGA Ethernet
Display Graphical, bright colored 6.5 inches TFT touch screen (640 x 480 px) with customizable display layout Wetted parts PTFE, borosilicate glass
Industries Beverages Chemical Industry Cosmetics, Personal Care Electronics Environmental Food Industry Petroleum Industry Pharmacy, Medicine, Biotechnology Beverages Chemical Industry Cosmetics, Personal Care Education, Research Electronics Environmental Food Industry Petroleum Industry Pharmacy, Medicine, Biotechnology Beverages Chemical Industry Cosmetics, Personal Care Education, Research Electronics Environmental Pharmacy, Medicine, Biotechnology * After temperature equilibration

7. O₂ Meter: OxyQC

OxyQC is the precise O2 meter that remains unaffected by other dissolved gases. Whether for portable at-line use from process lines, tanks, kegs or casks during production process or as a stand-alone version for the laboratory - the OxyQC is indispensable for precise beverage analysis in beer, wine, juices and soft drinks as well as water.

When combined with Anton Paar’s PFD filling device, sample is taken directly from the package into the measuring chamber of OxyQC - with no loss of dissolved oxygen during sample transfer. OxyQC for the laboratory provides reliable O2 results, even out of very small packages.

For the utmost flexibility, the instrument’s new and robust design is small, compact and lightweight and therefore fully protected for harsh environments. It provides a battery life of up to ten hours. The integrated O2 Data Logger function enables continuous measurements from the line or tank.

Measuringrange O2 0 ppm to 4 ppm
Temperature -3 °C to +30°C (27°F to 86°F),
Accuracy: ±0.2 °C
Repeatabilitys.d. O2 ±2 ppb* Reproducibilitys.d.
O2 ±4 ppb** O2 ±10 ppb*** O2 ±20 ppb**** Resolution
O2 0.1 ppb < 100 ppb Additionalinformation Sample volume approx. 100 mL Measuring timeper sample approx. 50 seconds
Internalstorage 500 measured results Interfaces 1 x RS-232 for PC and printer 1 x USB for PC 1 x RFID, 1 x Bluetooth (optional) Protectionclass IP67 Power supply AC 100 - 240 V, 50/60 Hz,1.5 A DC 12 V, 3.0 A Rechargeablebattery type Li-Ion 11.1 V, 2.25 Ah(optional: Li-Ion 11.25 V, 2.6 Ah) Maximumat-line operation 10 hours Dimensions (Lx W x H) 262 mm x 209 mm x 176 mm(10.3 in x 8.2 in x 6.9 in) Weight 1.7 kg (3.75 lbs) *Valid for measuring range < 200 ppb **Valid for measuring range < 1000 ppb ***Valid for measuring range < 2000 ppb ****Valid for measuring range < 4000 ppb

8. Filling Device: PFD

The PFD Filling Device transfers your sample directly from a closed container - either a bottle or can - into the measuring chamber of a measuring instrument. As the closure is sealed before piercing, no CO2 is lost during sample transfer.


Can 0.5 L
Glass bottle 1 L
PET bottle 3 L
Compressed air 6 ± 0.5 bar (87 ± 7 psi) relative pressure
Dimensions (L x W x H) 190 x 270 x 760 mm (7.5 x 10.6 x 26.4 inches)
Maximum height with piercing head in highest position 1020 mm(40.2 inches) Weight 10.1 kg (22.3 lbs)

9. MCP 200/300/500 Modular Circular Polarimeter

MCP 200/300/500 is an automatic polarimeter for analyzing optically active substances. It is highly accurate and easy to use. The combination of quality, robust design and modern data management makes MCP 200/300/500 the most powerful polarimeter on the market. The instrument allows customer-specific configurations and provides the widest range of options for the future.MCP 200/300/500 meets all application requirements for the pharmaceutical, cosmetics, chemical and medical industries as well as for R&D.


°OR at 589 nm
MCP 200 MCP 300 MCP 500
Measuring range ±89.9° ±89.9° ±89.9° Resolution 0.001° / 0.0001° (optional) 0.001° / 0.0001° (optional) 0.0001°
Accuracy* ±0.002° (most precise measuring mode) ±0.005° (fast measuring mode) better than ±0.002° Repeatability ±0.002° ±0.002° better than ±0.001° Response time 12 seconds 12 seconds 15 seconds Wavelength 589 nm and optionally up to eight wavelengths. Standard spectral (365, 405, 436, 546, 578, 633, 880 nm), customer-specific wavelengths on request Sensitivity A light intensity control compensates attenuation up to an Optical Density (OD) of 4.0 Light source Tungsten halogen lamp, 6V, 20 W, with average lifetime of 2000h * under physical standard conditions Temperature interface MCP 200 MCP 300 MCP 500 Resolution 0.1°C 0.1°C 0.01°C Accuracy** ± 0.2°C ± 0.1°C ± 0.03°C Temperature control Peltier system for automatic temperature control between 10 °C and 45 °C Temperature control range*** 20 °C + 25 °C (optional 10 °C to 45 °C) 10 °C to 45 °C Sample cell ToolMaster™: Wireless automatic identification of sample cells via RFID, sample cell path length from 2.5 mm to 200 mm ** with Peltier module and Toolmaster™ sample cell (50/100/200 mm) *** the temperature control at 10 °C is under physical standard conditions.

10. Kinematic Viscosity: SVM 3000 Viscometer

The SVM 3000 Viscometer measures the dynamic viscosity and density of oils and fuels according to ASTM D7042. From this result, the viscometer automatically calculates the kinematic viscosity and delivers measurement results which are equivalent to ISO 3104 or ASTM D445.

The Stabinger measuring principle with Peltier thermostat enables an incomparably wide viscosity and temperature range with a single system. SVM 3000 is quick, compact and energy-saving, versatile in use, with only small amounts of sample and solvents required. This makes it the most efficient high-precision viscometer on the market.

Required sample volume (mL) 2.5 Minimum solvent consumption (mL per sample) 2.5 Typical solvent consumption (mL per sample) 10 Volume of the solvent bottles (L) 2 x 0.5 Max. filling viscosity (mPa.s) 2000 Typical value, dependent on sample type and temperature. Reproducibility * Viscosity 0.35 % within the works adjustment range 1 % outside this range Density (viscosity compensated) 0.0005 g/cm³ from 0.65 to 1.5 g/cm³ 0.0020 g/cm³ outside this range Temperature 0.02 °C (0.04 °F) from 15 to 105 °C (59 °F to 221 °F) 0.05 °C (0.09 °F) outside this range Repeatability* Viscosity 0.1 % Density 0.0002 g/cm³ Temperature 0.005 °C (0.01 °F) *Typical values, dependent on sample type and temperature. Measuring range Dynamic viscosity (mPa.s) 0.2 to 20 000* Density (g/cm³) 0.65 to 3 Temperature 15 to 105 °C 60 to 220 °F Lower temperatures on request. *Typical values, dependent on sample type and temperature. Sample throughput (per hour) Diesel fuel, fast test (ultrafast) 25 (30)* Engine oil, fast test (ultrafast) 15 (18)* 1000 mPa.s at 20 °C, standard test 8.5 (10)* Engine oil, double determination, standard test 7 (8)* * Values in parenthesis for compressed air drying. Data memory/modes 384 data sets/10 programmable modes Interfaces Dual RS-232, AT-keyboard Weight net/gross 15/17 kg 33/38 lbs Space requirements L x W x H440 x 315 x 220 mm 17.3 x 12.4 x 8.7" Ambient conditions 15 to 35 °C (59 to 95 °F), max. 80 % r.h. below 31 °C (88 °F), 67 % at 35 °C (95 °F) Power supply (sinusoidal current) 100 to 240 VAC, 50 to 60 Hz, 75 VA



Our Partners